U4 and U7 can use the same UVLO network #2
Reference in New Issue
Block a user
No description provided.
Delete Branch "%!s()"
Deleting a branch is permanent. Although the deleted branch may continue to exist for a short time before it actually gets removed, it CANNOT be undone in most cases. Continue?
Since U4 and U7 are the same IC drawing from the same power source, and EN is a high input impedance pin, they may use the same network to determine their UVLO. This will save the use of two seperate pots. Alternatively, you may choose to use a seperate battery protection circuit to determine this cut-off, and forgo the UVLO circuitry all-together.
they could however, one buck runs at 8 volts and one runs at 5, i would perfer to have a cut off higher for the 8 volt one so that the racer can still report back that it has reached a low enough voltage before fully turning off